Scroll Top

Power Transformers

Improve Reliability and Maximize Performance

INSPECTIONS

Site Inspections & Surveys

ASSEMBLY

Site Assembly & Installation Services

CONTROLS

Protection & Control Systems

COMMISSIONING

Testing & Commissioning Services

MAINTENANCE

Asset Management Services

REFURBISH

Factory Repairs & Refurbishments

TRFOCUS INSPECTIOnS

transformer internal & External inspections

Our Transformer Integrity Inspections focus on key areas such as Condition, Serviceability, Reliability Compliance. We also examine the internal structure of your power transformer at our Transformer Workshop.
TransformerServices_-_IntegralPower[1]

assembly TRANSFORMER

Integral Power is a Transformer Installation & Services partner for Hitachi Energy. This synergy brings together latest process and stringent procedures for Transformer assembly. Our qualified engineers & technicians ensure that best practices and latest equipment is used across our project portfolio.

Validated Procedures

All transformer installations are driven by industry best practices and validated assembly procedures that ensure superior service, every time.

Service Partnership

We partner with our customers to ensure that project/operational goals stay at the forefront, giving you access to a reliable delivery partner.

Latest
Equipment

We have access to latest plant, test equipment, fully fitted test vans & service vehicles, ready to be deployed to your project.

Protection and control systems

We integrate Protection, Control, and Monitoring systems into both new and existing Transformer Installations
Integral Power’s Testing and Commissioning Engineers perform extensive integration and functional testing of secondary circuits in order to prove that all circuits are fully functional, stable, and integrated as required. Current injection and voltage application across primary equipment followed by measurements and indications across corresponding secondary devices ensure end-to-end functionality and polarity of all connected circuits.

Transformer Testing & Commissioning An engineered approach

Our meticulously engineered client-specific commissioning plans, check sheets and test reports help substations transition through to energization in a safe, logical & step-by-step manner.

Testing & Commissioning by far, are the most complex and crucial pieces in the high voltage power puzzle that bind the design intent to the functional substation. Integral Power offers an extensive range of acceptance tests, functional verification and commissioning activities that are tailored to the needs of modern power infrastructure.

Transformer MAINTENANCE & ASSET MANAGEMENT

We not only provide maintenance but also work with our customers to prepare asset management plans, allowing stakeholders to forecast levels of maintenance expenditure & plan capital investment to manage their asset base.

Switchgear-Maintenance

ONLINE PREVENTATIVE MAINTENANCE

Our online predictive maintenance services can be performed while your system remains energized, eliminating costly shutdowns. By performing the following, we can help you identify when a failure may occur so you can plan an outage instead of dealing with an emergency.

Visual
Inspections

We inspect cleanliness, cracked insulators and bushings, condition of the paint, oil levels, oil leaks, oil/ winding temperature gauges, nitrogen pressures, relay targets, and condition of grounds.

Infrared Inspections

Our infrared Testing detects heat buildup, loose connections, and defective surge arrestors which are often a precursor to failure. Heat signatures are captured using latest IR thermal imaging equioment.

Ultrasonic Detection

Ultrasonic Detection identifies excessive corona which produces RF interference and may cause an insulator, bushing, or surge arrester to fail. prolem areas can be identified before a failure occurs.

Nitrogen Tests

Gas samples are taken and tested for Percent TCG, which identifies gas in the oil, caused by hot spots or overloading. The Percent Oxygen test, identifies moisture in oil.

Oil Analysis

Oil Analysis is conducted to identify the essential properties of transformer insulating oils and provides a more accurate assessment of their condition via their electical properties as well as dissovled gas analysis.

Partial Discharge

Partial Discharge Testing can be performed while equipment is on or offline and can be a reliable indicator of insulation quality and its impact on overall transformer health and performance.

Transformer repair & refurbish an economical alternative

Repair and refurbishment are proven methods that help extend the life of your transformer by up to 40 years, This is good news for your budget and for the environment.
Transformer-Inspection-Wide

RECENT PROJECTS

From commissioning Utility-scale Renewable Generation to Mission Critical High Voltage Power networks, Integral Power has been at the forefront in the power industry, Leveraging High Voltage Expertise to create value for customers.